{"product_id":"kidde-kf30r-hard-wired-mains-optical-heat-alarm-with-rechargeable-battery","title":"Kidde KF30R Hard Wired Mains Optical Heat Alarm with Rechargeable Battery","description":"\u003ch4 class=\"card-header ch2\" data-target=\"#tab-1\"\u003eDescription:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDust compensation and bug screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto reset after activation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTamper-resistant locking device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains operation â€“ Built-in rechargeable Lithium back-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Details:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMains-powered heat alarm that can be interlinked with up to 23 other Kidde mains alarms, be they ionisation, optical or heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOnce interlinked, the detection of the relevant danger by an individual unit will sound across all the connected alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains-powered heat alarms can be used throughout the home in humid or dusty environments where an optical or ionisation smoke alarm is unsuitable, e.g. kitchens, loft spaces and garages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe Firex range requires installation by a professionally qualified electrician and complies with UK Building Regulations for new housing and associated standards (Grade D BS 5839, Part 6).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInterlink with up to 23 Firex hard-wired alarms â€“ all alarms sound if danger is detected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm memory â€“ identifies source unit within interconnecting network\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined Test\/Hush button allows regular testing of alarm function and can be used to temporarily silence nuisance alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuto reset after activation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTamper-resistant locking device â€“ prevents unauthorised removal without the use of a tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMains operation â€“ Built-in rechargeable Lithium back-up tamper-proof battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModel KF30R\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Supply 230V mains-powered with rechargeable Lithium battery back-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature Range 0ÂºC to + 40ÂºC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity Range Up to 93% Relative Humidity (RH) non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage and Transport -20ÂºC to +60ÂºC and 5â€“95% relative humidity (RH) non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm Dimensions 127 x 127 x 39mm (not including heat sensor guard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBracket Dimensions 133 x 133 x 6mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm Weight 180g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWarranty 6 years (including battery)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprovals BSI certified to BS5446 Part 2: 2003\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCE tested and certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Thermistor (Thermal Resistor) within detection unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eButton Test Simulates the effect of heat at the sensor, checks electronics and sounder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Self-test Circuitry is tested and unit beeps (chirps) if fault is detected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage 230V AC, 50 Hz (nominal UK voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption \u0026lt; 15mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Push-in\/snap-fit type connector with 150mm long flying leads (supplied)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery Back-up Non user-replaceable 3 x 3V rechargeable Lithium Aluminium Alloy \/ Magnesium Composite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOxide cells (ML2430)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower-on Indicator Continuous green LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm Sounder Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses) with soldered contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSound Output 85dB (A) minimum at 3 metres\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm Frequency 3.2 kHz typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm Status Red LED flashes approx once every five minutes = normal operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRed LED flashes once a second = sensing heat in excess of 58ÂºC (sounder alarm sounds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterconnection Up to 24 Firex and Kidde â€˜Slickâ€™ units (smoke, heat and CO) can be hardwire interconnected with optional control (see below)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Controls Wired Remote Test and Hush Unit (REMTH) allows test and hush of interlinked units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Pattresses SMK23RU also has integral switchable relay for operating remote devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSMK4896 â€“ Surface mounting base for added ease of installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFixing Mounting bracket ring supplied with two â€˜Tâ€™ slot fitting option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e57mm spacing to a maximum of 90mm for standard screw fittings on back boxes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBracket has 50mm diameter central access hole for cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlastics used NORYL â€“ Cover, main body and mounting bracket\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLead-Free Status All Firex alarms are lead-free\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":58077652713846,"sku":"KF30R","price":39.74,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0781\/4437\/3036\/files\/KF30R.jpg?v=1781282088","url":"https:\/\/www.falconelectrical.co.uk\/products\/kidde-kf30r-hard-wired-mains-optical-heat-alarm-with-rechargeable-battery","provider":"Falcon Electrical","version":"1.0","type":"link"}